EP 0 455 014
U.S.Patent No. 5,415,176
U.S.Patent No. 6,473,641
U.S.Patent No. 6,477,409
U.S.Patent No. 6,480,736
U.S.Patent No. 6,487,445
U.S.Patent No. 6,532,385
U.S.Reissue Patent No. 37,954
Other patents pending
GB
D
Instruction Manual
Read this Instruction Manual carefully and keep it for future reference.
Bedienungsanleitung
Lesen Sie sich diese Bedienungsanleitung bitte sorgfältig durch und bewahren Sie sie zum späteren Nachschlagen auf.
F
Mode d’emploi
A lire attentivement et à garder en cas de besoin.
Tanita UK Ltd.
Tanita Europe GmbH
Dresdener Strasse 25
D-71065 Sindelfingen
Germany
Tel: +49 (0)-7031-6189-6
Fax: +49 (0)-7031-6189-71
Tanita France S.A.
Villa Labrouste
The Barn, Philpots Close, Yiewsley,
Middlesex, UB7 7RY UK
Tel: +44 (0)1895 438577
Fax: +44 (0)1895 438511
NL
I
Gebruiksaanwijzing
Deze handleiding aandachtig lezen en voor naslagdoeleinden bewaren.
68 Boulevard Bourdon
92200 Neuilly-Sur-Seine France
Tel: +33 (0)-1-55-24-99-99
Fax: +33(0)-1-55-24-98-68
Manuale di Istruzioni
Leggere attentamente questo manuale di istruzioni e conservarlo per consultazioni future.
Tanita Corporation
Tanita Corporation of America Inc.
2625 South Clearbrook Drive
Arlington Heights, IL 60005 USA
Tel: +1-847-640-9241
Fax: +1-847-640-9261
Tanita Health Equipment H.K. Ltd.
Unit 301-303 3/F Wing On Plaza
62 Mody Road, Tsimshatsui East
Kowloon, Hong Kong
Tel: +852 2838 7111
Fax: +852 2838 8667
14-2, 1-Chome, Maeno-Cho
Itabashi-Ku, Tokyo, Japan 174-8630
Tel: +81(0)-3-3968-2123
Fax: +81(0)-3-3967-3766
Manual de instrucciones
E
Lea detenidamente este manual de instrucciones y guárdelo para futura referencia.
Manual de instruções
P
Leia cuidadosamente este manual e guarde-o para futura referência.
ISO 9001 Certified
©2004 Tanita Corporation
BC5327801
GB
GB
Positioning the Monitor
SWITCHING THE WEIGHT MODE
You can change the unit indication by using the switch on the back of the scale as shown in the figure.
Place the measuring platform on a hard, flat surface where there is minimal
vibration to ensure safe and accurate measurement.
Note: To avoid possible injury, do not step on the edge of the platform.
Note: If weight mode is set to pounds or stone-pounds, the height programming mode will be automatically set to feet and inches.
Similarly, if kilograms is selected, height will be automatically set to centimeters.
Handling Tips
This monitor is a precision instrument utilizing state-of-the-art technology.
To keep the unit in the best condition, follow these instructions carefully:
Do not attempt to disassemble the measuring platform.
Store the unit horizontally, and place it so that the buttons will not be pressed accidentally.
Avoid excessive impact or vibration to the unit.
Place the unit in an area free from direct sunlight, heating equipment,
high humidity, or extreme temperature change.
Never submerge in water. Use alcohol to clean the electrodes and glass cleaner (applied to a cloth first) to keep
them shiny; avoid soaps.
SETTING AND STORING PERSONAL DATA IN MEMORY
You will receive readings only if data has been programmed into one of the personal data memories or the Guest mode.
The monitor can store personal details for up to 4 people.
Do not step on the platform when wet.
Do not drop any objects onto the platform.
1. Turn on the Power
Press the Set button to turn on the unit (once programmed, tapping a Personal
Key turns on the unit.) The unit will beep to confirm activation, the Personal Key
numbers (1,2,3,4) will be displayed, and the display will flash.
Note: If you don’t operate the unit for sixty seconds after the unit has been turned on, the unit
will turn off automatically.
GETTING ACCURATE READINGS
To ensure accuracy, readings should be taken without clothing and under consistent
conditions of hydration. If you do not undress, always remove your socks or stockings,
and be sure the soles of your feet are clean before stepping on the measuring platform.
Be sure that your heels are correctly aligned with the electrodes on the
measuring platform. Don t worry if your feet appear too large for the unit -
accurate readings can still be obtained if your toes overhang the platform.
It is best to take readings at the same time of day. Try to wait about three
hours after rising, eating, or hard exercise before taking measurements.
While readings taken under other conditions may not have the same
absolute values, they are accurate for determining the percentage of change
as long as the readings are taken in a consistent manner. To monitor
progress, compare weight and body fat percentage taken under the same
conditions over a period of time.
Note: If you make a mistake or want to turn the unit off before you have finished
programming it, press the Weight-Only Key (
) to force quit.
2. Select a Personal Key Number
Press the Up/Down buttons to select a Personal Key. Once you reach the
Personal Key number you wish to use, press the Set button. The unit will
beep once to confirm.
Toes may overhang
measuring platform
Heels centered on
electrodes
Note: An accurate reading will not be possible if
the soles of your feet are not clean, or if your
knees are bent or you are in a sitting position.
3. Set Age
The display defaults to Age 30 (range of user age is between 7-99). An
arrow icon appears on the lower left side to indicate Age setting. Use the
Up/Down buttons to scroll through numbers. When you reach your age,
press the Set button. The unit will beep once to confirm.
AUTOMATIC SHUT-DOWN FUNCTION
The automatic shut-down function shuts off the power automatically in the following cases:
If you interrupt the measurement process. The power will shut down automatically within 10 to 20 seconds,
depending upon the type of operation.
If an extreme weight is applied to the platform.
During programming, if you do not touch any of the keys or buttons within 60 seconds.*
After you have completed the measuring process.
4. Select Female or Male
Use the Up/Down buttons to scroll through Female ( ) or Male ( ),
Female/Athlete and Male/Athlete settings, then press the Set button. The
unit will beep once to confirm.
*Note: If the power shuts off automatically, repeat the steps from “Setting and Storing Personal Data in Memory” (p.3).
5. Specify the Height
The display defaults to 5’ 7.0” (170cm) (range of user is from 3’ 4.0”–7’
3.0” or 100cm – 220cm). Use the Up/Down buttons to specify Height and
then press the Set button. The unit will beep once to confirm.
The unit will beep twice and the display will flash all data (Male/Female,
Age, Height, etc.) three times to confirm the programming. The power will
then shut down automatically.
2
3
GB
GB
TAKING BODY COMPOSITION READINGS
1. Select Personal Key and Step On
Press
key to display Muscle Mass & Physique Rating.
Press
key to display Total Body Water % .
Press your pre-programmed Personal key.
(Release the key within 3 seconds or the display will show "Error".)
The unit will beep and the display will show the programmed date.
The unit will beep again and the display will show "0.0".
Now step onto the platform.
Note: If you step onto the platform before 0.0 appears the display will show Error and you
will not obtain a reading. Furthermore, if you do not step onto the measuring platform
within about 60 seconds after 0.0 appears, the power is shut-off automatically.
2. Obtain Your Readings
Your weight will be shown first.
Continue to stand on the platform.
"00000" will appear on the display and disappear one by one from left to right.
Your Body Fat percentage(%FAT) and Body Fat Range will appear on the display
screen.
Press
key to display BMR & Metabolic Age.
Press
key to display Visceral Fat % & Judge.
After your body fat percentage has been calculated, a black bar will flash along the bottom of the display,
identifying where you fall within the Body Fat Ranges for your age and gender
Note: Do not step off until Body Fat % is shown.
To see other readings press each feature key while weight & Body Fat % is displayed.
Press same feature key to display weight & Body Fat % again.
Note: The following readings are applicable only to adults aged 18 years to 99 years.
Press
key to display Previous weight &
Press
key to display Bone Mass.
Body Fat %.
Muscle Mass
/ Physique Rating
%TBW
BMR / Metabolic Age
Recall
Visceral Fat
Bone Mass
4
5
GB
PROGRAMMING THE GUEST MODE
Guest mode allows you to programme the unit for a one-time use
without resetting a Personal data number.
Press button to activate the unit. Then follow the steps:
Set Age, Select Female or Male, and Specify Height.
Note: If you step onto the platform before 0.0 appears the display will show Error and
you will not obtain a reading.
TAKING WEIGHT MEASUREMENT ONLY
Select Weight-Only Key
Press the Weight-only key. After 2 or 3 seconds, 0.0 will appear in the
display and the unit will beep. When 0.0 appears in the display, step onto
the platform. The body weight value will appear. If you remain on the platform,
the display will flash for about 30 seconds, and then the power will automatically turn off.
If you step off the platform, the weight will continue to show for about 5 seconds, then
0.0 will appear and the unit will shut off automatically.
TROUBLESHOOTING
If the following problems occur ...then...
A wrong weight format appears followed by kg, lb, or st-lb
Refer to Switching the Weight Mode on p.3.
Lo appears on the display, or all the data appears and immediately
disappears.
Batteries are low. When this message appears, be sure to replace the batteries immediately, since weak batteries will
affect the accuracy of your measurements. Change all the batteries at the same time with new AA-size batteries.
Note:Your settings will not be erased from the memory when you remove the batteries.
Error appears while measuring.
Please stand on the platform keeping movement to a minimum.
The unit cannot accurately measure your weight if it detects movement.
The Body Fat Percentage is more than 75%, readings cannot be obtained from the unit.
The Body Fat Percentage reading does not appear or ----- appears after
the weight is measured.
Your personal data has not been programmed. Follow the steps on p.3.
Make sure socks or stockings are removed, and the soles of your feet are clean and properly aligned with the guides
on the measuring platform.
OL appears while measuring.
Reading cannot be obtained if the weight capacity is exceeded.
6
|